# What backup heat should a heat pump have in Colorado?

> Electric strips, dual fuel with a gas furnace, or little backup at all: how each covers a Colorado cold snap, how it is sized and how the controls decide.

URL: https://sundogauroraheatpumps.com/guide/heat-pump-backup-heat/

Backup heat covers the hours a heat pump cannot carry the house alone. The choice is between electric strips, a gas furnace, or a small backup, and your house and rates decide it.

Most Colorado heat pumps use one of two backups: electric resistance strips in the indoor air handler, or a gas furnace in a dual-fuel setup. Some well-insulated houses with a strong cold-climate unit need only a small strip. Which fits depends on the house's heat loss, the unit's output at 5°F, your panel and your gas and electric rates.

No option is cheapest for every house. We size the backup to the gap our [load calculation](https://sundogauroraheatpumps.com/guide/heat-pump-sizing/) finds, and we show you the cold-night numbers before you choose between [dual fuel](https://sundogauroraheatpumps.com/dual-fuel-heat-pump/) and an all-electric system.

## The three ways to cover the cold hours

Each option does the same job, heat for the hours below the balance point and during defrost, with different trade-offs. Backup also matters on the night something fails: if the outdoor unit stops, the backup is what keeps the pipes and the house warm until it is repaired, so we never size it to zero without talking it through.

|  | Electric strip backup | Dual fuel (gas furnace) | Small or no backup |
| --- | --- | --- | --- |
| How it works | Resistance coils in the air handler switch on in stages | The furnace takes over below a set outdoor temperature | The heat pump carries nearly all hours; a small strip covers defrost |
| What it needs | Panel capacity for the strip circuit | A furnace in good shape whose blower and coil match the heat pump | Low heat loss and strong 5°F output |
| Running cost depends on | Your electric rate; strips deliver 1 unit of heat per unit of electricity | Your gas rate and furnace efficiency | Mostly the heat pump's efficiency |
| Watch for | Strips running when the heat pump can carry the load | A changeover set by habit, not by numbers | A cold-snap shortfall if the load was guessed |

## Sizing electric backup to the gap

One kilowatt of resistance heat delivers 3,412 BTU per hour. That makes strip sizing simple arithmetic once the load calculation is done.

### The math

A 5 kW strip delivers about 17,000 BTU per hour; a 10 kW strip about 34,000. At 240 volts, 10 kW draws roughly 42 amps before the circuit is sized, which is why a strip that is bigger than the gap costs panel space it never uses.

### Staging and lockout

Strips should come on in stages and stay locked out above an outdoor temperature where the heat pump can carry the house. Without a lockout, a thermostat can call for strips on a mild morning simply because the house is recovering. Our [panel guide](https://sundogauroraheatpumps.com/guide/electrical-panel-for-heat-pump/) covers the circuits.

## How a dual-fuel system decides which one runs

In a dual-fuel house the controls switch from heat pump to furnace at a changeover temperature. There are two ways to set it, and the better changeover uses both.

### The comfort point

The balance point: the outdoor temperature where the heat pump stops keeping up with the house. Below it, the furnace has to take over or the house cools.

### The cost point

Compare the cost of 100,000 BTU of delivered heat. From gas, that is one therm divided by the furnace's efficiency. From the heat pump, it is 29.3 kWh times your electric rate divided by the heat pump's COP at that temperature. We run it on your own Xcel rates.

## Controls make or break the backup

The same equipment can run efficiently or expensively depending on how the controls are set up. These are the settings we confirm at start-up and leave in writing with you.

- An outdoor sensor, so changeover and lockout follow the actual temperature
- Strip lockout above a set outdoor temperature, and staged strips below it
- Defrost tempering, so the backup warms the air briefly while the coil defrosts
- A thermostat that knows it is running a heat pump, with the right number of stages
- Gentle recovery after a setback, so a morning warm-up doesn't bring on the strips

## Should I turn the thermostat down at night?

With a furnace, deep setbacks save gas. With a heat pump, the answer depends on the backup and the controls.

### Electric strip backup

A small setback of a few degrees, or none, usually works best. A deep setback can make the morning recovery call on the strips, the most expensive heat in the house.

### Dual fuel

Setbacks behave more like they did with the furnace, because the furnace handles recovery on cold mornings. The changeover setting still matters.

### Smart thermostats

Many offer a heat-pump recovery mode that warms the house slowly. We set it to match the backup you have.

## Which backup fits which house

These are the places we start the conversation, not fixed answers.

### Lean toward dual fuel

The furnace has good years left, the AC is the part that failed, or the panel has little room for a large strip. See [furnace-to-heat-pump conversion](https://sundogauroraheatpumps.com/heat-pump-conversion/) if you are weighing it.

### Lean toward electric backup

The furnace is near the end of its life, the house has room on the panel, you want to drop gas, and a [cold-climate model](https://sundogauroraheatpumps.com/cold-climate-heat-pump-installation/) covers most of the load at 5°F.

### Lean toward a small backup

Newer, tighter houses with a low heat loss, where the 5°F output of the chosen unit covers the design load or nearly does. A small strip still covers defrost and a failed outdoor unit.

## Choosing with your numbers

Bring a year of Xcel bills to the visit and we can set the changeover and size the strips from them. Call Sundog at [(719) 417-2475](tel:+17194172475) or [request an estimate](https://sundogauroraheatpumps.com/contact/). The [heat pump vs gas furnace guide](https://sundogauroraheatpumps.com/guide/heat-pump-vs-gas-furnace/) and [operating cost guide](https://sundogauroraheatpumps.com/guide/heat-pump-operating-cost-colorado/) go deeper on the money side.

## Questions people ask

### Is electric backup heat expensive to run?

Per unit of heat, resistance strips cost more to run than a working heat pump, because they deliver one unit of heat per unit of electricity. Sized to the gap and locked out in mild weather, they run for a small share of the winter.

### Can I keep my old furnace as the backup?

Often, if it is in good condition and its blower and coil can work with the heat pump. We check both on the visit; a furnace near the end of its life usually makes more sense to replace with the job.

### Does backup heat come on during defrost?

In most setups, yes, briefly. It tempers the air while the outdoor coil defrosts so the registers don't blow cool air for those few minutes.

## Related service

Dual-fuel heat pump

A heat pump for most of the winter, your gas furnace for the coldest nights, and controls that decide which one runs.

## More guides

Aurora heat pump planning guide

The whole decision in the order it gets made: how a ducted heat pump works, what it does in the cold, how it is sized, what happens to your furnace, ducts and panel, and what it costs to buy and run.

Cold-weather performance

A heat pump keeps heating when it is cold outside, just with less output as the temperature drops.

Heat pump sizing

Size comes from what your house loses on a cold night and gains on a hot afternoon, matched to equipment by its output in the cold.