What size heat pump does my Aurora house need?

Size comes from what your house loses on a cold night and gains on a hot afternoon, matched to equipment by its output in the cold. Here is how that works and what to ask for.

Heat pump outdoor unit in the side yard of a Parker two-storyThe same house in a thermal rendering
Daylight and thermal views of the same house: where it loses heat sets the load.

Last Updated: November 2026

Your house needs a heat pump sized to its own heat loss, worked out room by room with a Manual J load calculation, and chosen by its heating output at 5°F rather than its nominal tons. That number often comes in below the label on the old furnace or AC, and in Aurora the heating load usually decides the size.

Every estimate visit for heat pump installation with Sundog includes that room-by-room calculation, along with duct, airflow and panel checks, so the size on your written estimate comes from your house and not from the last system.

Why the old tonnage is the wrong starting point

Matching the old nameplate repeats whatever guess was made 20 or 30 years ago, before windows were replaced, the attic was topped up or a basement was finished. A heat pump also punishes a wrong size in both directions.

Too big

An oversized unit reaches temperature fast and shuts off. On mild days it runs in short bursts, wears the compressor, and in summer it stops before it pulls moisture out of the air. It also costs more to buy, and the ducts have to carry more air than they may be able to.

Too small

An undersized unit runs flat out whenever the weather turns and leans on backup heat for more hours than it needs to. The house still gets warm, but more of that heat comes from the strip or the furnace instead of the heat pump.

SmallerLargerHeat pump size against the house'scalculated loadToo small: runs flat out and leanson backup heat for more hoursSized to the loadToo big: short cycles, damp summerair, more air than the ducts maycarry

What a load calculation actually measures

A Manual J calculation, published by ACCA, adds up every path heat takes in and out of the house at local design conditions. We measure it on site rather than estimating from square footage.

  • Wall area and insulation, room by room, including knee walls and rooms over garages
  • Window sizes, glass type and which way each window faces
  • Ceiling and attic insulation depth, and any vaulted or flat roof sections
  • Air leakage, judged from the age and tightness of the house
  • Where the ducts run, since ducts in an attic or crawlspace lose heat before it reaches the room
  • For cooling: sun on the windows, people, appliances and humidity
  1. Walls: area and insulation, room by room
  2. Windows: size, glass and the way each faces
  3. Ceiling and attic insulation
  4. Air leakage
  5. Ducts in the attic lose heat before it reaches the room

From BTUs to tons: how the numbers turn into equipment

One ton of capacity is 12,000 BTU per hour. Here is how the math runs for a house whose calculation shows a heating load of 36,000 BTU per hour at design conditions and a cooling load of 24,000.

StepWhat it tells youThe worked numbers
Heating load at designHeat the house loses on a cold design night36,000 BTU/h
Cooling loadHeat the house gains on a hot afternoon24,000 BTU/h, about 2 tons
Heat pump output at 5°FWhat the outdoor unit delivers in the cold, from the manufacturer's dataA 3-ton cold-climate unit listing 27,000 BTU/h
Gap at designHeat the backup has to supply on the coldest hours9,000 BTU/h
Backup to cover it1 kW of electric heat is 3,412 BTU/hAbout 2.6 kW, so the smallest common 5 kW strip

The gap at the bottom of the table is why sizing and backup are one decision. A slightly larger cold-climate unit shrinks the gap; a much larger one oversizes the cooling side. Manual S, ACCA's equipment-selection method, sets the limits on that trade, and variable-speed equipment eases it because it slows down on mild days.

Heating load at design: 36,000 BTU/h27,000 BTU/h from the 3-toncold-climate unit at 5°F9,000 BTU/h gap: about 2.6 kW, so a5 kW strip

Want your own number? We start from your house and your bills.

Get an Estimate

Your ducts get a vote too

A heat pump needs a set amount of air across its indoor coil, usually somewhere around 350 to 450 cubic feet per minute per ton depending on the manufacturer. Size the equipment up and the ducts must carry more air.

What we check

We measure static pressure at the blower and look at return size and the far runs. If the ducts are already near their limit, a larger unit makes noise and loses airflow instead of adding comfort.

What it changes

Sometimes the right answer is the smaller unit plus a second return. The ductwork guide explains the readings, and the electrical panel guide covers the circuit side of a size change.

What to ask for on any estimate

Square-foot rules miss too much: two houses of the same size on the same street can differ by a ton because of windows, insulation and duct location. That is why we don't publish a tonnage calculator. These questions tell you whether a quote was sized to your house.

Was a room-by-room load calculation done?

Ask to see the heating and cooling totals and the room list. A single number with no rooms behind it is a guess.

What is the output at 5°F?

The nominal tons say little about winter. Ask for the low-temperature capacity of the matched indoor and outdoor units, which our written estimate lists next to the model numbers.

How big is the backup, and why?

The backup should match the gap at design, not the whole house. Our cold-weather guide shows why that gap exists.

Were the ducts checked for the new airflow?

A size with no static-pressure reading behind it assumes the ducts are fine.

Should I insulate or air-seal before sizing?

If attic insulation or air sealing is already planned, do it first or at least decide on it first. The load calculation is only as good as the house it describes.

Sealing and insulating first

The heating load drops, sometimes enough to move the house down a size or shrink the backup. We run the calculation on the planned improvements and note them on the estimate.

Sizing the house as it is

Fine when no envelope work is planned. Adding insulation later still lowers bills and runtime; the system simply has a little more headroom than it needs.

Getting a size you can check

If you are comparing quotes that disagree by a ton, the load numbers settle it. Call Sundog at (719) 417-2475 or book an estimate visit; we measure the house, show you the totals and size the cold-climate heat pump to them. For the full decision in order, start with the Aurora heat pump planning guide, and see the installation cost page for what moves the price.

Get an Estimate

Questions people ask

Can I see the load calculation numbers?

Yes. You get the heating and cooling totals from the visit along with what we found in the ducts and panel, so you can compare our size with any other quote.

Should a heat pump in Aurora be sized for heating or cooling?

Heating usually decides it here, because the house loses more heat on a cold night than it gains on a hot afternoon. We then check that the cooling side is not oversized for summer.

Is a bigger heat pump safer for cold nights?

Only up to a point. A cold-climate unit with good output at 5°F plus a right-sized backup covers cold nights better than an oversized unit that short-cycles the rest of the year.

Get an estimate for your Aurora house

Tell us about the house and the rooms that give you trouble. We come back with a first range from our typical rates and a time for the site visit.